Securitron UNL-24 UNLATCH Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Para a casa Securitron UNL-24 UNLATCH. Securitron UNL-24 UNLATCH User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 10
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2011, all rights reserved PN# 500-18300
Page 1 Rev. D, 08/11
SECURITRON MODEL UNL-12, UNL-24 UNLATCH
®
MOTORIZED
ELECTRONIC STRIKE INSTALLATION AND OPERATING INSTRUCTIONS
1. DESCRIPTION
Securitron’s UnLatch is a revolutionary new type of electric strike which eliminates the
necessity to perform a routing operation on the door frame for installation. The motor
driven UnLatch also presents a fully concealed appearance on the door which not only
enhances the architectural appeal of the installation but improves security over a conventional
electric strike as an intruder is less able to determine the type of security device present on the
door. The UnLatch functions with cylindrical dead latches or spring latches and includes a
latch status output which reports when the door is in latched (secure) condition or is open.
Product Specifications are: Input Voltages: 12 VDC (UNL-12), +20%, -10%. 24 VDC
(UNL-24), +20%, -10%. Current: At rest: 40 mA (either voltage). When operating- 3 Amp
input surge @ 12 VDC; 1.5 Amp input surge @24 VDC for 100 milliseconds and 300 mA @ 12
VDC or 200 mA @ 24 VDC thereafter. Operating Temperature: -10 F to 125 F.
FIG 1: UNLATCH DIMENSIONS (INCHES)
4.87
1.245
3.37
4.12
3.38
1.50
1.33
RECOMMENDED TOOLS
MEDIUM PHILLIPS DRIVER
MEDIUM SLOTTED DRIVER
CHISEL
WIRE CUTTER/STRIPPER
VOLT/OHM METER
CRIMP CONNECTORS
CRIMP PLIERS
2. PHYSICAL INSTALLATION
2.1 SURVEY
The installer must first be sure that the latch is of
the cylindrical type with or without the deadlatch
function. See Figure 2. Most North American latches
are of this type which is also called tubular. Examples
of latch types on which the UnLatch will not
function include many panic bar latches and rim
latches (rim latches are on the surface of the door
rather than being mortised into the middle of the
door). The UnLatch also will not function on mortise
latches. These are heavy duty rectangular units
similar in appearance to the drawing on the right.
After determining that there is a cylindrical latch, the
installer must determine whether there is a wooden,
or hollow metal (steel) door frame and whether the type of strike present on the frame is of the
ANSI 2 3/4” type (found on many residential doors) or the ANSI 4 7/8” strike (commercial).
MORTISE LATCHES
WILL NOT FUNCTION
WITH THE UNLATCH
Vista de página 0
1 2 3 4 5 6 7 8 9 10

Resumo do Conteúdo

Página 1 - MOTORIZED

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Página 2 - Page 2 Rev. D, 08/11

PN# 500-18300 Page 10 Rev. D, 08/11 TEMPLATE FOR CUTTING OUT ANSI 2 ¾” STRIKE PREPARATION AND INSTALLING UNLATCH ON WOODEN FRAME DOTTED

Página 3 - Page 3 Rev. D, 08/11

PN# 500-18300 Page 2 Rev. D, 08/11 FIG. 2: IDENTIFICATION OF CYLINDRICAL DEADLATCH AND SPRINGLATCH CYLINDRICAL DEADLATCH CYLINDRICAL SPRINGLAT

Página 4 - Page 4 Rev. D, 08/11

PN# 500-18300 Page 3 Rev. D, 08/11 FIG. 3: MOUNTING ON WOOD DOOR WITH ANSI 2 3/4” STRIKE ANSI 2 3/4"STRIKESTOPDRAW VERTICAL LINETHROUGH E

Página 5 - Page 5 Rev. D, 08/11

PN# 500-18300 Page 4 Rev. D, 08/11 If the amount of slack or rattling is less than 1/16-1/8”, you have a “tight” door and the ability of the do

Página 6 - Page 6 Rev. D, 08/11

PN# 500-18300 Page 5 Rev. D, 08/11 FIG 5: UNLATCH VIEW FROM ABOVE IN REST (SECURE) POSITION SPRING LATCHDEAD LATCHPINDEAD LATCH PLUNGERSPRING

Página 7 - Page 7 Rev. D, 08/11

PN# 500-18300 Page 6 Rev. D, 08/11 4. WIRING 4.1 GENERAL ELECTRICAL CHARACTERISTICS The UnLatch is a six wire device. Power (12 or 24VDC dep

Página 8 - Page 8 Rev. D, 08/11

PN# 500-18300 Page 7 Rev. D, 08/11 Note: The addition of the zener diodes is only required when using the UNL-24 with 24VAC transformer and br

Página 9

PN# 500-18300 Page 8 Rev. D, 08/11 of the door depends on it receiving constant power. Any time power is cut to the UnLatch, it will report th

Página 10 - Page 10 Rev. D, 08/11

PN# 500-18300 Page 9 Rev. D, 08/11 APPENDIX A: TROUBLESHOOTING PROBLEM-- Unit will not operate when trigger wire is connected to +V. On a new

Modelos relacionados UNL-12 UNLATCH

Comentários a estes Manuais

Sem comentários